Numerical Aperture
NA, half-angle and f-number
Edit either field and the other follows. Changing the medium holds whichever of the two you edited last.
Numerical aperture describes the cone of light an optic can accept or emit, as the sine of the maximum half-angle scaled by the refractive index of the medium the cone travels in.
n is the refractive index of the medium, close to 1.00 for air. θ is the half-angle of the cone measured from the optical axis, so the full cone angle is 2θ. Confusing the two is the most common error with this quantity, which is why both are shown. NA cannot exceed n, and at NA = n the half-angle reaches 90 degrees.
Two f-numbers, and they are not the same
f/# = 1 / (2 · tan θ) paraxial
The first form holds for a well corrected system obeying the Abbe sine condition and is the one used for objectives and fibre optics. The second follows from the ray geometry of a thin lens and is the working f-number of classical lens design. They agree to within a percent below about 10 degrees and separate quickly after that: at a half-angle of 30 degrees they differ by a quarter. In air the sine form cannot go below f/0.5, which is the physical limit at NA = 1.
Fibre numerical aperture
A fibre's NA comes from the index step between core and cladding, and it is defined for the acceptance cone in air. Enter that NA with the medium left at air to get the acceptance half-angle. Selecting fused silica as the medium gives something different and usually not what is wanted: the ray angle inside the core rather than the acceptance angle outside the fibre.
Assumptions
Refractive index varies with wavelength, and the values in the list are nominal figures for visible light. In the near infrared where TDLAS operates the difference is small but real, so enter the index at your own wavelength if precision matters. The calculation is geometric throughout and says nothing about aberration, vignetting, transmission or the actual intensity distribution within the cone, which for a laser beam is set by its divergence rather than by an aperture stop.
Application notes
Nitrous Oxide Monitoring in Wastewater Treatment: TDLAS for Laughing Gas Measurement
In Brief Nitrous oxide (N₂O) is a potent greenhouse gas produced during biological nitrogen removal in…
CO Monitoring in Waste Incineration: Combustion Control, Safety, and Compliance
In Brief Waste incineration produces CO concentrations that fluctuate rapidly and unpredictably because the fuel, municipal…
CO Analysis in Cement and Steel Production: Process Control, Safety, and Kiln Diagnostics
In Brief Carbon monoxide is one of the most informative gases in cement and steel production.…
Industrial Oxygen Measurement with TDLAS: Combustion Control, Inerting, and Process Monitoring
In Brief Oxygen measurement serves fundamentally different purposes depending on the application. In combustion, O₂ in…
Gas Analysis in Biogas Production: CO₂, CH₄, and H₂S Monitoring from Digester to Grid
In Brief Biogas production depends on a controlled anaerobic digestion process whose health and output are…
Combustion Gas Analysis in Power Plants: CO₂, CO, and O₂ for Efficiency and Emissions Control
In Brief Combustion optimization in power plants requires continuous measurement of exhaust gas composition, primarily CO…
Gas Analysis Across the Carbon Capture and Storage Chain: From Flue Gas to Geological Storage
In Brief Carbon capture and storage requires gas analysis at every stage of the process: measuring…
Oxygen Monitoring in Chemical Processes: Inerting Verification, Reaction Atmosphere Control, and Safety
In Brief Oxygen concentration is a critical control parameter in chemical manufacturing, where it determines whether…
Oxygen monitoring in confined spaces using TDLAS
In Brief Oxygen concentration in confined spaces must stay within the 19.5% to 23.5% range to…
Oxygen monitoring for combustion control using TDLAS
In Brief Combustion efficiency depends on maintaining the correct excess oxygen level in the flue gas.…
Gas monitoring in water and wastewater treatment using TDLAS
In Brief Water and wastewater treatment facilities produce and consume several gases that require continuous monitoring:…
TDLAS gas analyzers as process control instruments
In Brief A gas analyzer used for process control must meet requirements that go beyond analytical…
TALK TO OUR TDLAS EXPERTS
Interested in learning more?
Talk to an engineer or contact us to learn more about our products and technology, and explore how our next-generation TDLAS gas analyzers can solve your gas analysis applications.