What the measurement is for, where the analyzer sits, and what the data controls, organised by gas and process.
21 resources
Showing all 21
Application note
Nitrous oxide monitoring in wastewater treatment: TDLAS for laughing gas measurement
N₂O is a potent greenhouse gas produced during biological nitrogen removal. Emission factors vary widely between plants and over time.
Application note
Ammonia monitoring in wastewater treatment: TDLAS for gas-phase ammonia analysis
Treatment plants generate gas-phase ammonia at nearly every stage, from headworks through aeration, scrubbing and sidestream treatment.
Application note
Gas monitoring in water and wastewater treatment using TDLAS
Methane in digesters, hydrogen sulphide in sewers and sludge handling, oxygen in aeration basins, and carbon dioxide as a marker of biological activity.
Application note
Ammonia monitoring in agriculture: TDLAS for barn, scrubber and field emissions
Ammonia from livestock housing, manure storage and fertilizer application drives eutrophication and secondary particulate formation.
Application note
CO monitoring in waste incineration: combustion control, safety and compliance
CO concentrations fluctuate rapidly and unpredictably, because the waste fuel varies in composition, moisture and calorific value from load to load.
Application note
CO analysis in cement and steel production: process control, safety and kiln diagnostics
In cement kilns, CO tracks combustion quality in the rotary kiln and preheater tower, giving early warning of feed buildup and flame instability.
Application note
Carbon monoxide monitoring in combustion processes: early detection and process control
CO in combustion exhaust is a direct indicator of incomplete combustion, from poor air-fuel mixing through to flame instability.
Application note
Combustion gas analysis in power plants: CO₂, CO and O₂ for efficiency and emissions control
CO and O₂ control the air-fuel ratio. CO₂ indicates combustion completeness, fuel carbon conversion and emissions intensity.
Application note
Industrial oxygen measurement with TDLAS: combustion control, inerting and process monitoring
Oxygen measurement serves different purposes by application. In combustion it indicates excess air; in inerting it is a contaminant with a hard threshold.
Application note
Oxygen monitoring for combustion control using TDLAS
Combustion efficiency depends on holding the correct excess oxygen level in the flue gas. Too much O₂ wastes fuel by heating unnecessary air.
Application note
Oxygen monitoring in chemical processes: inerting verification, reaction atmosphere control and safety
Oxygen concentration is a critical control parameter in chemical manufacturing, determining whether reactions proceed as intended.
Application note
Oxygen monitoring in confined spaces using TDLAS
Oxygen must stay within 19.5% to 23.5% to protect workers and prevent fire hazards, without the calibration burden of electrochemical sensors.
Application note
Gas analysis in biogas production: CO₂, CH₄ and H₂S monitoring from digester to grid
The CO₂-to-CH₄ ratio indicates digester stability and energy content. H₂S concentration determines corrosion risk.
Application note
Gas analysis across the carbon capture and storage chain: from flue gas to geological storage
Gas analysis at every stage of the chain, starting with CO₂ removal efficiency at the capture plant.
Application note
TDLAS for greenhouse gas monitoring
Selective, stable over months, and fast enough to catch short emission events. Covers CO₂, CH₄, N₂O and H₂O across stack, process and open-air geometries.
Application note
TDLAS for fugitive emissions monitoring and leak detection
Fugitive emissions from valves, flanges, tanks and buried infrastructure are both a compliance liability and a direct product loss.
Application note
TDLAS for leak detection and fugitive emissions monitoring
LDAR needs instruments that separate the target gas from background species and hold calibration across a full survey shift.
Application note
Remote gas analysis with TDLAS: stand-off measurement for hazardous and inaccessible locations
Measures concentration along an optical path with no contact with the gas and no hardware installed at the measurement point.
Application note
High-speed TDLAS measurement for combustion, exhaust and outdoor gas monitoring
Combustion processes change gas composition on timescales of milliseconds to seconds, faster than most analyzers can follow.
Application note
Gas temperature measurement with TDLAS in heavy industry
TDLAS can measure gas temperature across an industrial process stream without physical contact with the gas.
Application note
Gas analysis with TDLAS in low-light-transmission environments
Dust, fog and condensed droplets attenuate the beam. Spectral fitting separates broadband attenuation from the gas-specific absorption signal.