Cost model · BeamCell® extractive vs process FTIR

How many species do you actually need to measure

FTIR resolves a broad spectrum in one instrument. A TDLAS analyzer scans a narrowband region around a small number of absorption lines. The cost comparison turns almost entirely on how many species your application requires, so that is the first thing this model asks.

count

One TDLAS analyzer covers a limited number of species. Above that, the comparison needs several analyzers and the arithmetic turns. This model finds the point where it turns and tells you which side of it you are on.

Process FTIR analyzer

EUR
EUR
EUR per year
EUR per year
Detector cooling and purge requirements vary by configuration. Some process FTIRs run a cooled detector with a recurring supply cost and others do not. Set this to whatever your quotation actually specifies, or to zero.

BeamCell® extractive analyzer

EUR
EUR
EUR per year
count, confirm with us for your gases
Shared assumptions and financing
count, applied to both
years
percent per year
display only, no conversion

Enter your figures above

The model runs as soon as the fields are filled.

Analyzers required

-

Cost per species, FTIR

-

Cost per species, BeamCell

-

Cost against number of species measured

FTIR BeamCell Your species count

Cost breakdown, present value over the horizon
Cost line FTIR BeamCell Difference
Tell us which gases you need Send us the species list and the sample conditions and we will confirm how many analyzers your application needs, or tell you if FTIR is the better instrument for it.

Method. Capital and installation fall in month zero. Service and consumables accrue evenly across the year. Everything is discounted to present value at the rate you set. The number of BeamCell analyzers is the species count divided by the species covered per analyzer, rounded up, and every cost on that side scales with the analyzer count. The measurement point count multiplies both sides equally.

The starting values are illustrative placeholders, not published prices for any product and not a quotation for any competing instrument. Replace them with the quotations you hold. Currency is a display label only and no conversion is applied, so enter every figure in the same currency.

What this model does not price. FTIR records a broad spectrum, so it can return species you did not specify when you bought it, which has real value if your permit conditions or your process change. It also handles unknown or unexpected components in a way a narrowband instrument cannot. Against that, a TDLAS analyzer scans a narrow region around selected absorption lines and can reach lower detection limits on those specific lines. Neither of those differences appears as a number here. If your species list is long or likely to grow, treat the cost result as one input among several rather than the answer.